Pasteurization of Milk
The primary purpose of pasteurization is to inactivate maximum pathogens (disorder-causing microorganism) in milk to make it more secure to eat (at the least reduction in 5 log cycles of the populace of Mycobacterium paratuberculosis; Stabel & Lambertz, 2004). Because of food protection issues, this procedure is extraordinarily regulated all around the international. There are basically 3 methods used to pasteurize milk: vat pasteurization (or low-temperature, long-time (LTLT)); high-temperature, quick-time (HTST) pasteurization; and ultra-pasteurization (or ultra high-temperature pasteurization (UHT) if aseptically packaged. The instances and temperature requirements are indexed in desk 17.3 as defined within the CFR (21 CFR 131). The regulations in addition country that every particle of a product must reach these temperatures, at a minimal, and be maintained at or above the temperature for a minimum of those times. The equipment used in pasteurization ought to be designed and often tested to meet this mandate. The PMO specifies that Grade A milk uncooked should contain less than one hundred, colony-forming devices in line with milliliter (CFU/mL) of a general cardio microorganism.
Summary
The primary purpose of pasteurization is to inactivate maximum pathogens (disorder-causing microorganism) in milk to make it more secure to eat (at the least reduction in 5 log cycles of the populace of Mycobacterium paratuberculosis; Stabel & Lambertz, 2004). Because of food protection issues, this procedure is extraordinarily regulated all around the international. There are basically 3 methods used to pasteurize milk: vat pasteurization (or low-temperature, long-time (LTLT)); high-temperature, quick-time (HTST) pasteurization; and ultra-pasteurization (or ultra high-temperature pasteurization (UHT) if aseptically packaged. The instances and temperature requirements are indexed in desk 17.3 as defined within the CFR (21 CFR 131). The regulations in addition country that every particle of a product must reach these temperatures, at a minimal, and be maintained at or above the temperature for a minimum of those times. The equipment used in pasteurization ought to be designed and often tested to meet this mandate. The PMO specifies that Grade A milk uncooked should contain less than one hundred, colony-forming devices in line with milliliter (CFU/mL) of a general cardio microorganism.
Things to Remember
- There are basically 3 methods used to pasteurize milk: vat pasteurization (or low-temperature, long-time (LTLT)); high-temperature, quick-time (HTST) pasteurization; and ultra-pasteurization (or ultra-high-temperature pasteurization (UHT) if aseptically packaged.
- Pasteurization is designed to kill 5 logs (a hundred,thousand CFU/ mL) of the heat-susceptible microorganism; pathogenic bacteria are warmness prone.
- The plates are formed such that they direct the drift of the product lightly throughout the surface and maximize the surface region of the plates
- Pasteurizers also are supplied with a set of valves, organized to divert the product float lower back via the pasteurizer while the product glide or temperature settings aren't met, known as the float diversion valve (FDV).
MCQs
No MCQs found.
Subjective Questions
No subjective questions found.
Videos
No videos found.

Pasteurization of Milk
Pasteurization of milk

The primary purpose of pasteurization is to inactivate maximum pathogens (disorder-causing microorganism) in milk to make it more secure to eat (at the least reduction in 5 log cycles of the populace of Mycobacterium paratuberculosis; Stabel & Lambertz, 2004). Because of food protection issues, this procedure is extraordinarily regulated all around the international. There are basically 3 methods used to pasteurize milk: vat pasteurization (or low-temperature, long-time (LTLT)); high-temperature, quick-time (HTST) pasteurization; and ultra-pasteurization (or ultra-high-temperature pasteurization (UHT) if aseptically packaged. The instances and temperature requirements are indexed in desk 17.3 as defined within the CFR (21 CFR 131). The regulations in addition country that every particle of a product must reach these temperatures, at a minimal, and be maintained at or above the temperature for a minimum of those times. The equipment used in pasteurization ought to be designed and often tested to meet this mandate. The PMO specifies that Grade A milk uncooked should contain less than one hundred, colony-forming devices in line with milliliter (CFU/mL) of a general cardio microorganism.
Pasteurization is designed to kill 5 logs (a hundred,thousand CFU/ mL) of the heat-susceptible microorganism; pathogenic bacteria are warmness prone. The motive why pasteurized milk is no longer sterile, and milk desires to be pasteurized, is that thermoduric microorganism endures HTST processing and may later reason spoilage in milk. The number one approach used within the fluid milk industry is HTST. In this method, there are 3 heat exchange sections:
Regeneration, heating, and cooling
These sections include stacks of corrugated (to allow performance via increasing the surface are of heat transfer) stainless-steel plates, in which the heating medium and product flow in separate trade plates . The plates are formed such that they direct the drift of the product lightly throughout the surface and maximize the surface region of the plates. The drift inside the heat exchangers can be concurrent or countercurrent glide. Concurrent glide is where both the heating medium and the product go with the flow in the identical route. This lowers performance warmness transfer as compared to the countercurrent go with the flow, wherein the heating medium and the fluid product flow in opposite directions. The regenerator segment has pasteurized heated product on one side of the plates and unpasteurized bloodless product on the alternative. This segment recovers much of the warmth from the pasteurized product, increasing the efficiency of the pasteurizer. The handiest energy that needs to be furnished is that lost to the atmosphere and that due to inefficiencies of the heat transfer. Pressures in these plates are arranged in order that if there should be a leak among the plates, the glide would always be from the pasteurized product into the unpasteurized product or the alternative heat change fluid. The heating segment is hooked up to the conserving tube .The heating phase brings the temperature up such that on the cease of the keeping tube, the product is at a temperature higher than the stated pasteurization temperature (i.e. seventy-two-degree celsius ) for at least the minimum time (i.e. 15 sec). The heat transfer fluid for this segment of the pasteurizer is most often hot water. To assure that each particle of a product is heated and held at the prescribed temperature and time, pasteurizers are furnished with a maintaining tube and timing pump. This tube’s duration has calculated the usage of the glide rate furnished with the aid of the timing pump to present, at a minimal, the prescribed maintain time. The timing pump’s speed is adjustable and the waft rate is tested and sealed by means of regulatory officials. The retaining tubes are established with an incline in order that they may go with the flow constantly back closer to the heating phase within the case of a shutdown.
Pasteurizers also are supplied with a set of valves, organized to divert the product float lower back via the pasteurizer while the product glide or temperature settings aren't met, known as the float diversion valve (FDV). The goal for all of the equipment applied in pasteurization is to guarantee that each particle passing via the device is subjected to the minimum time and temperature set by way of the regulatory organizations. In the cooling phase, the product cooled with the aid of the incoming product within the regenerator phase is, in addition, cooled to the preferred go out temperature. Options to plate heat exchangers can be tube within- tube heat exchangers, wherein one fluid passes inside a principal tube in one path even as the second one fluid passes inside the other route in a tube surrounding the primary tube. The product also can be heated directly through bringing it into direct contact with steam. The water for this reason introduced to the product is removed by means of vacuum evaporation downstream. Scraped floor warmness exchangers are used to heat treat fluids with particulate rely upon or higher viscosity. They have got scrapers that eliminate the product fouling of the heat exchanger partitions. There are additional methods of pasteurization, along with vat, UP, and UHT. Vat pasteurization differs in that the heating fluid passes around the jacket of a specifically designed tank. So that you can prevent infection from condensate dripping into the pasteurizing fluid, the temperatures above the fluid in the tank must be above that of the fluid always. Since the temperatures are lower for vat pasteurization, the system instances are always longer to attain the identical kill off pathogens. The equipment for UP and UHT pasteurization is similar to HTST except for the time and temperatures involved. UP entails better temperatures (with shorter hold times) than HTST. The number one gain of UP and UHT is that the product is rendered essentially commercially sterile whilst combined with aseptic packaging (as with UHT), which permits for shelf stability.
Guidelines establish the minimum layout and instrumentation for all varieties of pasteurization. The sanitary fabrication, creation, and design of dairy system were enforced based totally on the requirements set up by way of the countrywide convention on Interstate Milk Shipments (NCIMS) .Some other independent organization that has advanced the three-A standards for the dairy industry is the three-A Sanitary Stds., Inc.
References
Cassida, L.E Jr.Industrial microbiology.New age into publishers, 1996.
I, Stever.Biochemistry.new york Wall freeman company, 1995.
JE, Smith.Biotechnology.Sinauer Association, 2000.
Nelson, D L and M M Cox.Leininger Principle of Biochemistry.Fifth. Freeman publication, 2004.
Lesson
Biotechnology in diary industry
Subject
Microbiology
Grade
Bachelor of Science
Recent Notes
No recent notes.
Related Notes
No related notes.